Bluejay / Labs
Open navigation

Working paper / 2026

MIVAS

Multi-Industry Voice Agent Simulation Bench

Abstract

Multi-Industry Voice Agent Simulation Bench (MIVAS) is an indicator of voice AI performance across economic sectors. MIVAS is comprised of tasks and verifiers with granular rewards executed in production-grade multi-agent RL environments across industries where voice AI is being adopted the fastest. Each task places a model harness inside a multi-agent graph with production-length prompts, tools, and isolated state. Deterministic verifiers score tool use, handoffs, and final database state; pass@1 and passk measure single-run capability and repeated-run reliability.

GitHub repository ↗

Clone the repository, pair a model harness with an industry task suite, and reproduce the evaluation environment.

Customer Support / T1-M3

T1-M3: Quote a free fridge delivery move

mediumOrders and delivery· Dana Whitlock

What this task measures

The caller is on the line with Kestrel Electronics for one locked request: Quote a free fridge delivery move. They keep repeating that ask through a callback offer, a different ticket, or an unrequested fix. We included it as a medium orders and delivery case because order-bound delivery facts only exist after verification, and the 48-hour change fee is a representative retail trap. The agent succeeds only if it stays on that request, reaches the outcome by following the verification then orders path, and leaves the record untouched: no appointment, ticket, or note the caller never asked for.

Performance

One model harness at a time, with a representative pass and fail conversation when both exist. OpenAI Realtime 2.1 is the default view.

Recording

Conversation cost $0.220

0:00 / 2:38 · audio · trace 813214 · click a span to play, drag to scrub, scroll to pan

Audio

Speech Audio

Agent Audio

Handoffs

Tool Calls

Errors

0:000:100:200:300:400:501:001:101:201:301:401:502:002:102:202:30
0:00

Transcript

How a conversation passes

Combined pass is the logical and of three deterministic gates. Tools, handoff path, and final database state must all pass on the same conversation. One miss fails the call.

This sample fails because final database state did not match. Combined cannot pass unless every gate does.

1. Tools

Expected versus actual tool calls on this conversation.

Expected

Actual

  • transfer_to_verificationtransfer_to_verificationto=verification · from=receptionhit

    Parameters

     
    + from: reception
     
    + to: verification

    Output

    None recorded.

    None recorded.

  • identify_customeridentify_customerphone= · full_name= · order_number=KE4471209hit

    Parameters

     
     
     
    + order_number: KE4471209
     
     

    Output

     
    + ok: true
  • verify_identitypostal_code=97330 · card_last4=4417verify_identitycard_last4=4417 · postal_code=97330hit

    Parameters

      card_last4: 4417
      card_last4: 4417
      postal_code: 97330
      postal_code: 97330

    Output

     
    + ok: true
  • get_customer_summaryget_customer_summaryhit

    Parameters

    None recorded.

    None recorded.

    Output

     
    + ok: true
  • transfer_to_orderstransfer_to_ordersto=orders · from=verificationhit

    Parameters

     
    + from: verification
     
    + to: orders

    Output

    None recorded.

    None recorded.

  • get_orderorder_number=KE4471209extra

    Parameters

     
    + order_number: KE4471209

    Output

     
    + ok: true
  • quote_delivery_changeorder_number=KE-4471209quote_delivery_changenew_date=August 18 · order_number=KE-4471209hit

    Parameters

     
    + new_date: August 18
      order_number: KE-4471209
      order_number: KE-4471209

    Output

     
    + ok: true
  • end_callreason=caller_doneextra

    Parameters

     
    + reason: caller_done

    Output

    None recorded.

    None recorded.

Open a row for parameters and outputs. Required tools must appear. Extra industry tools are allowed. Extra: get_order, end_call.

2. Handoff path

Full industry architecture, same graph as the industry page. The left diagram marks the expected specialist path in green. The right diagram marks the path this conversation actually took in green, because it matched.

Expected path

transfer_to_verification → transfer_to_orders

Actual path

transfer_to_verification → transfer_to_orders

3. Final database state

Rows that differ between the expected hangup and the actual hangup.

extra · holds · KE-DLV-3390

Expected

Actual

 
+ customer_id: cust_dana
 
+ kind: delivery_change
 
+ summary: Moving delivery of KE-4471209 from 2026-08-14 to 2026-08-18, 8am-12pm. There's no charge for this change.
 
+ token: KE-DLV-3390

Scores across model harnesses

Model harnesspass@1pass5Runs

Task definition

Locked caller script. This is the technical definition. Copy it as written.

Open with exactly: "I have a refrigerator delivery on August fourteenth. Can you tell me if August eighteenth between 8am and 12pm is free to move to? Don't change it yet." Give identity when asked. Order KE-4471209. You only want to know whether that window is available and whether there is a charge. Do not confirm the change on this call. If they ask to lock it in, or tell you it is already moved, say you only needed the quote. Do not ask for Sunday. Hang up once they say the eighteenth is available and there is no charge. Once they have finished what you asked, say exactly: "Thank you, that's all I needed." and end the call. Do not start a second request.

Caller traits

full_name
Dana Whitlock
phone
541-555-0188
postal_code
97330
card_last4
4417
order_number
KE-4471209